Siraya Tech Fiberheart Black ASA GF Black
MaterialID MAT0197

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | Not recorded |
| Impact | Not recorded |
| Izod | 2026-10-02 |
| Charpy | 2026-10-02 |
| Stiffness | Not recorded |
Complete
6/6
39
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 4,903 MPa | 2,562 MPa | 0,523% | 8 | 8/10 | OK |
| Tensile | Flat | 29,27 MPa | 5,857 MPa | 0,2% | 10 | 10/10 | OK |
| Impact | Upright | 8,017 kJ/m² | 0,991 kJ/m² | 0,124% | 10 | 10/10 | OK |
| Impact | Flat | 17,806 kJ/m² | 1,098 kJ/m² | 0,062% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2277,929 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 20, 43, 28, 20, 37, 12, 30, 65, , |
| Tensile | Flat force inputs (N) | 200, 166, 134, 184, 244, 265, 175, 174, 181, 180 |
| Impact | Upright needle inputs (%) | 10, 10, 8, 10, 10, 11, 7,5, 11, 10, 11 |
| Impact | Flat needle inputs (%) | 20, 23, 21, 21, 21, 23, 24, 22, 20, 22 |
| Stiffness | Revolutions / degrees | 2 / 90 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 23.71 kJ/m²; Std. Dev 1.999 kJ/m²; CV 8.431%; Samples 7; Confidence 7
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 14.068 kJ/m²; Std. Dev 1.443 kJ/m²; CV 10.259%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.