Public test session report

Siraya Tech Fiberheart Brown PET GF Brown

MaterialID MAT0206

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-07-30
Impact2026-07-30
Stiffness2026-07-30
Status
Complete
Result modules
3/3
Specimen/result records
41
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright4,26 MPa2,167 MPa0,509%1010/10OK
TensileFlat47,711 MPa10,396 MPa0,218%1010/10OK
ImpactUpright101,697 kJ/m²31,892 kJ/m²0,314%1010/10OK
ImpactFlat376,548 kJ/m²23,353 kJ/m²0,062%1010/10OK
StiffnessThree-point bend2562,67 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)26, 58, 8, 10, 32, 35, 26, 24, 23, 35
TensileFlat force inputs (N)380, 304, 334, 333, 356, 179, 366, 354, 287, 209
ImpactUpright needle inputs (%)4, 4, 8, 5, 6, 4,5, 8, 8, 8,5, 4,5
ImpactFlat needle inputs (%)20, 20, 22, 22, 21, 23, 23, 23, 23, 24
StiffnessRevolutions / degrees2 / 0

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF