Public test session report

Eryone Standard Black PA6 CF Black

MaterialID MAT0212

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-08-01
Impact2026-09-19
Izod2026-10-01
Charpy2026-10-01
Stiffness2026-09-14
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
39
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright10,767 MPa2,716 MPa0,252%88/10OK
TensileFlat37,76 MPa9,535 MPa0,253%1010/10OK
ImpactUpright2,132 kJ/m²1,079 kJ/m²0,506%1010/10OK
ImpactFlat10,083 kJ/m²0,894 kJ/m²0,089%1010/10OK
StiffnessThree-point bend3237,057 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)86, 60, 78, 82, 35, 60, 72, 87, ,
TensileFlat force inputs (N)324, 279, 172, 264, 286, 117, 271, 263, 274, 205
ImpactUpright needle inputs (%)1, 2, 3, 1, 2, 2,5, 4, 4, 2, 5
ImpactFlat needle inputs (%)12,5, 12,5, 11,5, 13, 13, 12, 13, 14, 12, 10
StiffnessRevolutions / degrees1 / 210

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 4.815 kJ/m²; Std. Dev 0.399 kJ/m²; CV 8.281%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 4.684 kJ/m²; Std. Dev 0.635 kJ/m²; CV 13.564%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.