Public test session report

Eryone Standard Black ASA CF Black

MaterialID MAT0213

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-07-31
Impact2026-08-01
Izod2026-10-02
Charpy2026-10-02
Stiffness2026-07-31
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
39
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright2,884 MPa0,853 MPa0,296%88/10OK
TensileFlat18,196 MPa7,294 MPa0,401%1010/10OK
ImpactUpright5,549 kJ/m²0,513 kJ/m²0,092%1010/10OK
ImpactFlat12,4 kJ/m²0,677 kJ/m²0,055%1010/10OK
StiffnessThree-point bend2223,039 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)20, 15, 13, 20, 28, 11, 20, 23, ,
TensileFlat force inputs (N)212, 136, 105, 79, 103, 82, 165, 155, 84, 62
ImpactUpright needle inputs (%)6, 6,5, 6, 6,5, 8, 7, 7,5, 7, 7, 7
ImpactFlat needle inputs (%)16, 14,5, 16, 14,5, 15, 14,5, 15,5, 16,5, 14, 15
StiffnessRevolutions / degrees2 / 110

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 11.78 kJ/m²; Std. Dev 5.7 kJ/m²; CV 48.387%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 23.206 kJ/m²; Std. Dev 2.795 kJ/m²; CV 12.046%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.