Public test session report

Eryone Standard Black ASA CF Black

MaterialID MAT0213

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-07-31
Impact2026-08-01
Stiffness2026-07-31
Status
Complete
Result modules
3/3
Specimen/result records
39
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright2,884 MPa0,853 MPa0,296%88/10OK
TensileFlat18,196 MPa7,294 MPa0,401%1010/10OK
ImpactUpright115,228 kJ/m²10,653 kJ/m²0,092%1010/10OK
ImpactFlat257,483 kJ/m²14,067 kJ/m²0,055%1010/10OK
StiffnessThree-point bend2223,039 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)20, 15, 13, 20, 28, 11, 20, 23, ,
TensileFlat force inputs (N)212, 136, 105, 79, 103, 82, 165, 155, 84, 62
ImpactUpright needle inputs (%)6, 6,5, 6, 6,5, 8, 7, 7,5, 7, 7, 7
ImpactFlat needle inputs (%)16, 14,5, 16, 14,5, 15, 14,5, 15,5, 16,5, 14, 15
StiffnessRevolutions / degrees2 / 110

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF