Public test session report

Eryone Standard White ASA White

MaterialID MAT0216

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-07-31
Impact2026-08-01
Stiffness2026-07-31
Status
Complete
Result modules
3/3
Specimen/result records
37
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright2,725 MPa1,16 MPa0,426%77/10OK
TensileFlat34,094 MPa3,872 MPa0,114%99/10OK
ImpactUpright104,226 kJ/m²28,402 kJ/m²0,273%1010/10OK
ImpactFlat924,145 kJ/m²28,34 kJ/m²0,031%1010/10OK
StiffnessThree-point bend2120,83 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)23, 14, 26, 12, 22, 5, 22, , ,
TensileFlat force inputs (N)246, 186, 237, 223, 236, 240, 190, 192, 245,
ImpactUpright needle inputs (%)5, 4,5, 6, 6, 4,5, 9,5, 7, 4,5, 7,5, 7,5
ImpactFlat needle inputs (%)63, 59, 61, 61, 57, 58, 57, 58, 55, 57
StiffnessRevolutions / degrees2 / 150

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF