Public test session report

Eryone Standard Radiant Gold PLA Silk Yellow

MaterialID MAT0219

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v60.0.6 WORKFLOW-RELIABILITY - Bug Fixes and Workflow Reliability
2026-08-25 19:04:35

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-07-31
Impact2026-08-01
Stiffness2026-07-31
Status
Complete
Result modules
3/3
Specimen/result records
36
Public details
Approved

Specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright2,666 MPa1,154 MPa0,433%66/10OK
TensileFlat29,5 MPa10,289 MPa0,349%1010/10OK
ImpactUpright82,142 kJ/m²14,279 kJ/m²0,174%1010/10OK
ImpactFlat211,935 kJ/m²19,197 kJ/m²0,091%99/10OK
StiffnessThree-point bend2027,607 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)16, 21, 28, 21, 9, 9, , , ,
TensileFlat force inputs (N)241, 183, 277, 145, 72, 214, 236, 135, 270, 145
ImpactUpright needle inputs (%)4, 4, 4, 5, 6, 4,5, 5, 5, 5, 6,5
ImpactFlat needle inputs (%)10, 12, 12,5, 12, 13, 13, 13, 13, 14,
StiffnessRevolutions / degrees2 / 190

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF