Public test session report
Prusa3D Buddy3D PLA Silk Blue
MaterialID MAT0223

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-08-04 |
| Impact | 2026-08-04 |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | 2026-08-04 |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
41
41
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 5,122 MPa | 3,075 MPa | 0,6% | 10 | 10/10 | OK |
| Tensile | Flat | 33,992 MPa | 9,796 MPa | 0,288% | 10 | 10/10 | OK |
| Impact | Upright | 5,795 kJ/m² | 0,582 kJ/m² | 0,1% | 10 | 10/10 | OK |
| Impact | Flat | 12,69 kJ/m² | 1,051 kJ/m² | 0,083% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2838,65 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 62, 54, 19, 42, 48, 12, 50, 6, 17, 23 |
| Tensile | Flat force inputs (N) | 308, 203, 153, 213, 320, 145, 209, 262, 251, 146 |
| Impact | Upright needle inputs (%) | 7, 7, 6, 6,5, 7,5, 8, 7, 7, 8,5, 7 |
| Impact | Flat needle inputs (%) | 16, 14, 15, 16, 17, 17, 14, 15, 17, 14 |
| Stiffness | Revolutions / degrees | 1 / 290 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF