Public test session report
Spectrum The Filament Vivid Red PLA Hight Temp Red
MaterialID MAT0224

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-08-13 |
| Impact | 2026-08-13 |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | 2026-08-11 |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
40
40
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 2,563 MPa | 0,48 MPa | 0,187% | 9 | 9/10 | OK |
| Tensile | Flat | 22,241 MPa | 7,154 MPa | 0,322% | 10 | 10/10 | OK |
| Impact | Upright | 3,632 kJ/m² | 1,08 kJ/m² | 0,297% | 10 | 10/10 | OK |
| Impact | Flat | 11,076 kJ/m² | 2,718 kJ/m² | 0,245% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2084,884 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 13, 18, 18, 21, 15, 21, 14, 17, 13, |
| Tensile | Flat force inputs (N) | 176, 150, 104, 129, 171, 211, 118, 98, 210, 79 |
| Impact | Upright needle inputs (%) | 1, 4, 5, 5,5, 5, 5, 5, 5,5, 4, 5 |
| Impact | Flat needle inputs (%) | 14, 13, 10, 13, 13, 13, 12,5, 18, 20, 9 |
| Stiffness | Revolutions / degrees | 2 / 165 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF