Public test session report

Spectrum Smart Sky Blue PCTG Blue

MaterialID MAT0227

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-08-16
Impact2026-08-16
IzodNot recorded
CharpyNot recorded
Stiffness2026-08-16
Rigid test status
Partial
Rigid result modules
4/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright11,105 MPa3,265 MPa0,294%1010/10OK
TensileFlat42,851 MPa3,61 MPa0,084%1010/10OK
ImpactUpright6,907 kJ/m²1,546 kJ/m²0,224%1010/10OK
ImpactFlat15,373 kJ/m²2,926 kJ/m²0,19%1010/10OK
StiffnessThree-point bend1537,602 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)52, 60, 83, 54, 99, 57, 112, 86, 61, 58
TensileFlat force inputs (N)221, 258, 292, 285, 283, 290, 290, 295, 299, 273
ImpactUpright needle inputs (%)4, 7, 9,5, 10, 10, 9,5, 7,5, 8,5, 9,5, 9,5
ImpactFlat needle inputs (%)21, 17, 19, 21, 16,5, 12, 15,5, 24, 19,5, 22
StiffnessRevolutions / degrees3 / 120

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF