Public test session report
Spectrum Smart Sky Blue PCTG Blue
MaterialID MAT0227

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-08-16 |
| Impact | 2026-08-16 |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | 2026-08-16 |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
41
41
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 11,105 MPa | 3,265 MPa | 0,294% | 10 | 10/10 | OK |
| Tensile | Flat | 42,851 MPa | 3,61 MPa | 0,084% | 10 | 10/10 | OK |
| Impact | Upright | 6,907 kJ/m² | 1,546 kJ/m² | 0,224% | 10 | 10/10 | OK |
| Impact | Flat | 15,373 kJ/m² | 2,926 kJ/m² | 0,19% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 1537,602 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 52, 60, 83, 54, 99, 57, 112, 86, 61, 58 |
| Tensile | Flat force inputs (N) | 221, 258, 292, 285, 283, 290, 290, 295, 299, 273 |
| Impact | Upright needle inputs (%) | 4, 7, 9,5, 10, 10, 9,5, 7,5, 8,5, 9,5, 9,5 |
| Impact | Flat needle inputs (%) | 21, 17, 19, 21, 16,5, 12, 15,5, 24, 19,5, 22 |
| Stiffness | Revolutions / degrees | 3 / 120 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF