Public test session report
Spectrum Premium Navy Blue PETG Blue
MaterialID MAT0229

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-08-15 |
| Impact | 2026-08-15 |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | 2026-08-15 |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
41
41
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 8,613 MPa | 5,845 MPa | 0,679% | 10 | 10/10 | OK |
| Tensile | Flat | 34,991 MPa | 10,583 MPa | 0,302% | 10 | 10/10 | OK |
| Impact | Upright | 5,673 kJ/m² | 0,819 kJ/m² | 0,144% | 10 | 10/10 | OK |
| Impact | Flat | 11,368 kJ/m² | 2,684 kJ/m² | 0,236% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2073,171 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 30, 115, 32, 58, 90, 77, 104, 15, 22, 17 |
| Tensile | Flat force inputs (N) | 302, 115, 229, 182, 311, 258, 293, 132, 249, 204 |
| Impact | Upright needle inputs (%) | 5, 8,5, 7,5, 7,5, 6, 7, 7, 6,5, 7, 8 |
| Impact | Flat needle inputs (%) | 8,5, 13, 16,5, 13,5, 16, 16, 17, 14,5, 16, 8 |
| Stiffness | Revolutions / degrees | 2 / 170 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF