Public test session report
Spectrum Premium Tooling Yellow PLA Yellow
MaterialID MAT0230

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-08-15 |
| Impact | 2026-08-15 |
| Izod | Not recorded |
| Charpy | Not recorded |
| Stiffness | 2026-08-15 |
Rigid test status
Partial
Partial
Rigid result modules
4/6
4/6
Rigid specimen/result records
41
41
Public details
Approved
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 18,334 MPa | 6,728 MPa | 0,367% | 10 | 10/10 | OK |
| Tensile | Flat | 40,698 MPa | 7,634 MPa | 0,188% | 10 | 10/10 | OK |
| Impact | Upright | 6,782 kJ/m² | 0,824 kJ/m² | 0,121% | 10 | 10/10 | OK |
| Impact | Flat | 9,297 kJ/m² | 0,93 kJ/m² | 0,1% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 3237,057 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 176, 73, 149, 133, 86, 88, 84, 177, 158, 68 |
| Tensile | Flat force inputs (N) | 204, 320, 349, 190, 281, 242, 289, 274, 229, 268 |
| Impact | Upright needle inputs (%) | 7, 7, 7,5, 8, 10, 9, 8,5, 8,5, 9,5, 8,5 |
| Impact | Flat needle inputs (%) | 9,5, 12, 11,5, 11, 10, 11,5, 11,5, 11, 13, 13 |
| Stiffness | Revolutions / degrees | 1 / 210 |
Approved test notes
Method and equipment context
Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.
Testing methodology · Engineering methodology whitepaper · Download PDF