Yasin Standard Black PLA CF Black
MaterialID MAT0234

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-08-19 |
| Impact | 2026-08-20 |
| Izod | 2026-09-29 |
| Charpy | 2026-09-28 |
| Stiffness | 2026-08-19 |
Complete
6/6
41
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 3,784 MPa | 2,383 MPa | 0,63% | 10 | 10/10 | OK |
| Tensile | Flat | 38,575 MPa | 6,787 MPa | 0,176% | 10 | 10/10 | OK |
| Impact | Upright | 7,277 kJ/m² | 1,4 kJ/m² | 0,192% | 10 | 10/10 | OK |
| Impact | Flat | 15,419 kJ/m² | 0,875 kJ/m² | 0,057% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 2580,591 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 39, 41, 9, 24, 9, 18, 34, 50, 6, 16 |
| Tensile | Flat force inputs (N) | 260, 291, 245, 285, 169, 296, 294, 253, 219, 196 |
| Impact | Upright needle inputs (%) | 4,5, 9, 10, 8, 9,5, 9,5, 9,5, 9, 10, 10,5 |
| Impact | Flat needle inputs (%) | 20, 20, 18, 17, 20, 18, 18, 19,5, 19, 18,5 |
| Stiffness | Revolutions / degrees | 1 / 355 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 5.204 kJ/m²; Std. Dev 0.33 kJ/m²; CV 6.348%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 6.324 kJ/m²; Std. Dev 0.61 kJ/m²; CV 9.647%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.