Public test session report

Yasin Standard Black PETG GF Black

MaterialID MAT0235

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-08-19
Impact2026-08-20
Izod2026-09-30
Charpy2026-09-30
Stiffness2026-08-20
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
40
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright6,016 MPa3,812 MPa0,634%99/10OK
TensileFlat36,591 MPa7,789 MPa0,213%1010/10OK
ImpactUpright6,699 kJ/m²0,757 kJ/m²0,113%1010/10OK
ImpactFlat13,435 kJ/m²1,483 kJ/m²0,11%1010/10OK
StiffnessThree-point bend2713,415 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)12, 66, 26, 29, 31, 73, 30, 12, 73,
TensileFlat force inputs (N)263, 272, 173, 209, 275, 183, 170, 295, 301, 238
ImpactUpright needle inputs (%)7, 7, 9, 8,5, 8, 10, 9, 8, 8, 8
ImpactFlat needle inputs (%)15, 16, 13,5, 14, 17, 18, 19, 16,5, 18, 17
StiffnessRevolutions / degrees1 / 320

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 5.867 kJ/m²; Std. Dev 0.103 kJ/m²; CV 1.762%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 6.159 kJ/m²; Std. Dev 0.2 kJ/m²; CV 3.245%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.