Public test session report

Yasin Standard Green PCTG Green

MaterialID MAT0238

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-08-20
Impact2026-08-20
IzodNot recorded
CharpyNot recorded
Stiffness2026-08-20
Rigid test status
Partial
Rigid result modules
4/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright8,044 MPa3,704 MPa0,46%1010/10OK
TensileFlat26,793 MPa12,068 MPa0,45%1010/10OK
ImpactUpright2,656 kJ/m²0,768 kJ/m²0,289%1010/10OK
ImpactFlat9,091 kJ/m²1,263 kJ/m²0,139%1010/10OK
StiffnessThree-point bend1583,796 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)69, 25, 16, 61, 56, 32, 88, 43, 49, 84
TensileFlat force inputs (N)189, 99, 49, 244, 246, 158, 115, 266, 113, 263
ImpactUpright needle inputs (%)4, 3, 2,5, 1,5, 3, 5, 4, 3, 3,5, 3,5
ImpactFlat needle inputs (%)12,5, 8,5, 11, 11,5, 10, 10, 10, 12, 13,5, 12,5
StiffnessRevolutions / degrees3 / 85

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF