Public test session report

Bedrock 3D Standard Black ABS Plus Black

MaterialID MAT0246

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-09-05
Impact2026-09-11
Izod2026-09-29
Charpy2026-09-29
Stiffness2026-09-05
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
37
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright2,102 MPa0,581 MPa0,276%66/10OK
TensileFlat20,841 MPa4,139 MPa0,199%1010/10OK
ImpactUpright5,593 kJ/m²1,359 kJ/m²0,243%1010/10OK
ImpactFlat55,276 kJ/m²3,658 kJ/m²0,066%1010/10OK
StiffnessThree-point bend1091,788 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)17, 11, 12, 19, 14, 9, , , ,
TensileFlat force inputs (N)111, 88, 169, 160, 160, 130, 112, 122, 146, 157
ImpactUpright needle inputs (%)5, 7, 8, 8, 7, 7, 8, 8, 3, 8
ImpactFlat needle inputs (%)95, 95, 95, 94, 60, 95, 95, 95, 78, 94
StiffnessRevolutions / degrees4 / 250

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 65.708 kJ/m²; Std. Dev 9.686 kJ/m²; CV 14.741%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 123.714 kJ/m²; Std. Dev 9.88 kJ/m²; CV 7.986%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.