Public test session report

Bedrock 3D Standard Natural PA6 Natural

MaterialID MAT0247

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-09-06
Impact2026-09-11
Izod2026-09-29
Charpy2026-09-29
Stiffness2026-09-06
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright16,95 MPa11,78 MPa0,695%1010/10OK
TensileFlat60,293 MPa2,768 MPa0,046%1010/10OK
ImpactUpright11,49 kJ/m²2,286 kJ/m²0,199%1010/10OK
ImpactFlat32,162 kJ/m²7,436 kJ/m²0,231%1010/10OK
StiffnessThree-point bend1984,002 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)48, 208, 85, 180, 55, 48, 260, 66, 86, 66
TensileFlat force inputs (N)395, 374, 417, 357, 406, 403, 382, 388, 409, 389
ImpactUpright needle inputs (%)11,5, 9,5, 17,5, 16, 18, 15, 12, 14, 15, 12
ImpactFlat needle inputs (%)49, 35, 37, 32, 34, 48, 42, 24, 61, 42
StiffnessRevolutions / degrees2 / 210

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.667 kJ/m²; Std. Dev 0.676 kJ/m²; CV 40.568%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.965 kJ/m²; Std. Dev 0.697 kJ/m²; CV 35.483%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.