Bedrock 3D Standard Black PA6 HighTemp CF Black
MaterialID MAT0248

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-09-07 |
| Impact | 2026-09-11 |
| Izod | 2026-09-29 |
| Charpy | 2026-09-29 |
| Stiffness | 2026-09-06 |
Complete
6/6
39
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 7,383 MPa | 1,912 MPa | 0,259% | 9 | 9/10 | OK |
| Tensile | Flat | 68,633 MPa | 10,728 MPa | 0,156% | 9 | 9/10 | OK |
| Impact | Upright | 8,761 kJ/m² | 1,421 kJ/m² | 0,162% | 10 | 10/10 | OK |
| Impact | Flat | 22,973 kJ/m² | 3,691 kJ/m² | 0,161% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 5271,778 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 39, 50, 55, 39, 30, 56, 38, 70, 55, |
| Tensile | Flat force inputs (N) | 504, 359, 504, 371, 405, 504, 361, 504, 504, |
| Impact | Upright needle inputs (%) | 11, 9, 12, 13, 9,5, 9, 14, 10, 10, 10 |
| Impact | Flat needle inputs (%) | 33, 32, 26, 32, 36, 25, 24, 25, 25, 23 |
| Stiffness | Revolutions / degrees | 0 / 350 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 8.43 kJ/m²; Std. Dev 0.595 kJ/m²; CV 7.053%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 9.935 kJ/m²; Std. Dev 0.655 kJ/m²; CV 6.594%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.