Public test session report

Bedrock 3D Standard Natural PET Natural

MaterialID MAT0252

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-09-11
Impact2026-09-11
Izod2026-09-29
Charpy2026-09-29
Stiffness2026-09-11
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
34
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright1,23 MPa0,308 MPa0,25%33/10OK
TensileFlat31,039 MPa9,164 MPa0,295%1010/10OK
ImpactUpright2,535 kJ/m²0,787 kJ/m²0,311%1010/10OK
ImpactFlat4,12 kJ/m²0,898 kJ/m²0,218%1010/10OK
StiffnessThree-point bend2580,591 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)10, 8, 6, , , , , , ,
TensileFlat force inputs (N)173, 277, 255, 273, 148, 262, 144, 179, 189, 118
ImpactUpright needle inputs (%)2, 1,5, 3, 4, 4, 4, 3,5, 3,5, 4, 2
ImpactFlat needle inputs (%)5, 6,5, 5, 4,5, 6, 4, 5, 7, 4,5, 3,5
StiffnessRevolutions / degrees1 / 355

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.648 kJ/m²; Std. Dev 0.132 kJ/m²; CV 7.992%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 0.841 kJ/m²; Std. Dev 0.28 kJ/m²; CV 33.34%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.