Coex 3D Prime Scarlet Red PLA Red
MaterialID MAT0264

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-09-25 |
| Impact | 2026-09-26 |
| Izod | 2026-09-29 |
| Charpy | 2026-09-28 |
| Stiffness | 2026-09-25 |
Complete
6/6
41
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 13,104 MPa | 2,958 MPa | 0,226% | 10 | 10/10 | OK |
| Tensile | Flat | 40,605 MPa | 5,883 MPa | 0,145% | 10 | 10/10 | OK |
| Impact | Upright | 3,997 kJ/m² | 0,778 kJ/m² | 0,195% | 10 | 10/10 | OK |
| Impact | Flat | 9,794 kJ/m² | 1,88 kJ/m² | 0,192% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 3024,791 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 67, 90, 103, 97, 110, 43, 90, 76, 88, 88 |
| Tensile | Flat force inputs (N) | 259, 289, 241, 223, 200, 249, 316, 304, 255, 304 |
| Impact | Upright needle inputs (%) | 4,5, 3, 4, 5,5, 5, 5, 5, 5,5, 6,5, 5,5 |
| Impact | Flat needle inputs (%) | 17, 10, 14, 10,5, 13, 11, 12, 9, 11,5, 12 |
| Stiffness | Revolutions / degrees | 1 / 250 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 2.277 kJ/m²; Std. Dev 0.053 kJ/m²; CV 2.346%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 3.754 kJ/m²; Std. Dev 0.222 kJ/m²; CV 5.914%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.