Public test session report

Coex 3D Prime Scarlet Red PLA Red

MaterialID MAT0264

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-09-25
Impact2026-09-26
Izod2026-09-29
Charpy2026-09-28
Stiffness2026-09-25
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright13,104 MPa2,958 MPa0,226%1010/10OK
TensileFlat40,605 MPa5,883 MPa0,145%1010/10OK
ImpactUpright3,997 kJ/m²0,778 kJ/m²0,195%1010/10OK
ImpactFlat9,794 kJ/m²1,88 kJ/m²0,192%1010/10OK
StiffnessThree-point bend3024,791 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)67, 90, 103, 97, 110, 43, 90, 76, 88, 88
TensileFlat force inputs (N)259, 289, 241, 223, 200, 249, 316, 304, 255, 304
ImpactUpright needle inputs (%)4,5, 3, 4, 5,5, 5, 5, 5, 5,5, 6,5, 5,5
ImpactFlat needle inputs (%)17, 10, 14, 10,5, 13, 11, 12, 9, 11,5, 12
StiffnessRevolutions / degrees1 / 250

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 2.277 kJ/m²; Std. Dev 0.053 kJ/m²; CV 2.346%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 3.754 kJ/m²; Std. Dev 0.222 kJ/m²; CV 5.914%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.