Coex 3D Standard Scarlet Red PLA Red
MaterialID MAT0265

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-09-25 |
| Impact | 2026-09-26 |
| Izod | 2026-09-28 |
| Charpy | 2026-09-28 |
| Stiffness | 2026-09-25 |
Complete
6/6
41
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 23,579 MPa | 4,054 MPa | 0,172% | 10 | 10/10 | OK |
| Tensile | Flat | 38,744 MPa | 7,844 MPa | 0,202% | 10 | 10/10 | OK |
| Impact | Upright | 5,345 kJ/m² | 0,716 kJ/m² | 0,134% | 10 | 10/10 | OK |
| Impact | Flat | 8,347 kJ/m² | 0,734 kJ/m² | 0,088% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 3127,326 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 121, 122, 168, 173, 167, 168, 107, 184, 161, 162 |
| Tensile | Flat force inputs (N) | 185, 325, 182, 280, 278, 195, 311, 237, 259, 267 |
| Impact | Upright needle inputs (%) | 4,5, 7, 7, 6, 7, 7, 6, 7, 7, 7,5 |
| Impact | Flat needle inputs (%) | 9, 11, 11,5, 9,5, 9, 11, 10,5, 10, 10, 11 |
| Stiffness | Revolutions / degrees | 1 / 230 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 2.659 kJ/m²; Std. Dev 0.373 kJ/m²; CV 14.039%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 3.198 kJ/m²; Std. Dev 0.186 kJ/m²; CV 5.808%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.