Public test session report

Coex 3D Standard Scarlet Red PLA Red

MaterialID MAT0265

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-09-25
Impact2026-09-26
Izod2026-09-28
Charpy2026-09-28
Stiffness2026-09-25
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright23,579 MPa4,054 MPa0,172%1010/10OK
TensileFlat38,744 MPa7,844 MPa0,202%1010/10OK
ImpactUpright5,345 kJ/m²0,716 kJ/m²0,134%1010/10OK
ImpactFlat8,347 kJ/m²0,734 kJ/m²0,088%1010/10OK
StiffnessThree-point bend3127,326 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)121, 122, 168, 173, 167, 168, 107, 184, 161, 162
TensileFlat force inputs (N)185, 325, 182, 280, 278, 195, 311, 237, 259, 267
ImpactUpright needle inputs (%)4,5, 7, 7, 6, 7, 7, 6, 7, 7, 7,5
ImpactFlat needle inputs (%)9, 11, 11,5, 9,5, 9, 11, 10,5, 10, 10, 11
StiffnessRevolutions / degrees1 / 230

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 2.659 kJ/m²; Std. Dev 0.373 kJ/m²; CV 14.039%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 3.198 kJ/m²; Std. Dev 0.186 kJ/m²; CV 5.808%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.