Public test session report

Coex 3D Standard Banana Yellow PETG Yellow

MaterialID MAT0266

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-09-26
Impact2026-09-26
Izod2026-09-29
Charpy2026-09-28
Stiffness2026-09-26
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright13,412 MPa6,291 MPa0,469%1010/10OK
TensileFlat35,145 MPa4,517 MPa0,129%1010/10OK
ImpactUpright4,895 kJ/m²0,806 kJ/m²0,165%1010/10OK
ImpactFlat10,911 kJ/m²2,637 kJ/m²0,242%1010/10OK
StiffnessThree-point bend1826,854 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)134, 38, 109, 127, 57, 135, 106, 82, 23, 61
TensileFlat force inputs (N)266, 252, 245, 253, 215, 229, 173, 231, 188, 233
ImpactUpright needle inputs (%)6,5, 5, 6, 6, 6,5, 7, 5, 5, 8, 5,5
ImpactFlat needle inputs (%)11,5, 15, 11, 12, 17, 12,5, 12,5, 19, 15, 8
StiffnessRevolutions / degrees2 / 290

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.946 kJ/m²; Std. Dev 0.245 kJ/m²; CV 12.608%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 1.109 kJ/m²; Std. Dev 0.542 kJ/m²; CV 48.87%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.