Coex 3D Standard Banana Yellow PETG Yellow
MaterialID MAT0266

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39
Measurement provenance
Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.
| Module | Measured date |
|---|---|
| Tensile | 2026-09-26 |
| Impact | 2026-09-26 |
| Izod | 2026-09-29 |
| Charpy | 2026-09-28 |
| Stiffness | 2026-09-26 |
Complete
6/6
41
Approved
Rigid specimen and result quality
| Module | Orientation | Average | Std. dev. | CV | Specimens | Confidence | Validation |
|---|---|---|---|---|---|---|---|
| Tensile | Upright | 13,412 MPa | 6,291 MPa | 0,469% | 10 | 10/10 | OK |
| Tensile | Flat | 35,145 MPa | 4,517 MPa | 0,129% | 10 | 10/10 | OK |
| Impact | Upright | 4,895 kJ/m² | 0,806 kJ/m² | 0,165% | 10 | 10/10 | OK |
| Impact | Flat | 10,911 kJ/m² | 2,637 kJ/m² | 0,242% | 10 | 10/10 | OK |
| Stiffness | Three-point bend | 1826,854 MPa | n/a | n/a | 1 | Complete | OK |
Recorded native inputs
| Module | Input set | Recorded values |
|---|---|---|
| Tensile | Upright force inputs (N) | 134, 38, 109, 127, 57, 135, 106, 82, 23, 61 |
| Tensile | Flat force inputs (N) | 266, 252, 245, 253, 215, 229, 173, 231, 188, 233 |
| Impact | Upright needle inputs (%) | 6,5, 5, 6, 6, 6,5, 7, 5, 5, 8, 5,5 |
| Impact | Flat needle inputs (%) | 11,5, 15, 11, 12, 17, 12,5, 12,5, 19, 15, 8 |
| Stiffness | Revolutions / degrees | 2 / 290 |
Approved test notes
Method and equipment context
Testing methodology · Engineering methodology whitepaper · Download PDF
Izod and Charpy Impact Strength
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.946 kJ/m²; Std. Dev 0.245 kJ/m²; CV 12.608%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 1.109 kJ/m²; Std. Dev 0.542 kJ/m²; CV 48.87%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.