Public test session report

Coex 3D Standard Carbon Filled PLA CF Black

MaterialID MAT0268

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:10:39

Traceability boundary: canonical per-module measured dates are shown below. Session identifier, time of day, operator, printer/slicer profile and environmental conditions are Not recorded and are never inferred.

Measurement provenance

Canonical SQLite measured dates use ISO format; missing dates remain Not recorded.

ModuleMeasured date
Tensile2026-09-25
Impact2026-09-26
Izod2026-09-29
Charpy2026-09-28
Stiffness2026-09-25
Rigid test status
Complete
Rigid result modules
6/6
Rigid specimen/result records
41
Public details
Approved

Rigid specimen and result quality

ModuleOrientationAverageStd. dev.CVSpecimensConfidenceValidation
TensileUpright11,828 MPa4,201 MPa0,355%1010/10OK
TensileFlat39,959 MPa8,351 MPa0,209%1010/10OK
ImpactUpright6,001 kJ/m²0,573 kJ/m²0,096%1010/10OK
ImpactFlat10,248 kJ/m²1,111 kJ/m²0,108%1010/10OK
StiffnessThree-point bend3548,312 MPan/an/a1CompleteOK

Recorded native inputs

ModuleInput setRecorded values
TensileUpright force inputs (N)90, 106, 31, 56, 115, 61, 97, 74, 91, 48
TensileFlat force inputs (N)202, 319, 149, 259, 248, 308, 312, 288, 283, 230
ImpactUpright needle inputs (%)7,5, 6, 8, 8, 8, 7,5, 8, 7,5, 7, 6,5
ImpactFlat needle inputs (%)12, 12,5, 13, 10,5, 13, 15, 13,5, 11, 13,5, 11,5
StiffnessRevolutions / degrees1 / 160

Approved test notes

Method and equipment context

Purpose-built tensile, pendulum impact and three-point bend apparatus are used with the governed Settings Manager constants consumed by ResultsService. Results are comparative and do not claim accredited-laboratory equipment.

Testing methodology · Engineering methodology whitepaper · Download PDF

Izod and Charpy Impact Strength

Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 7.664 kJ/m²; Std. Dev 2.03 kJ/m²; CV 26.494%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.

Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 5.197 kJ/m²; Std. Dev 0.4 kJ/m²; CV 7.707%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.