Public Material Summary
Dataset identity, public test coverage, material/manufacturer distribution and the complete public score ledger.
Open HTML · PDF
Use only for fun, not for any professional comparison
Explore the allowlisted MaterialID, comparison, manufacturer, test-session, printing-recommendation and dataset reports.
Open Engineering Reports tab · Standalone directoryThis database is continuously expanding. YouTube review buttons open 3DPIceland Labs reviews when available, while Product page buttons open the manufacturer or reseller page for the filament. Public report buttons appear only for MaterialIDs explicitly selected for public reporting in the Engineering Platform. If a review link is missing or not working yet, the review video is still in production or scheduled for a future release.
Saved measurement summaries for materials included in this website export. This static section does not follow the interactive table filters or rankings.
Izod Impact Strength · run 1 · 2026-09-21 · Condition 1 · All batches
Printed on long side; bed-facing surface and layer/notch directions unconfirmed; specimen: ; notch: Unconfirmed
Standard reference: ISO 180 (reference only); Unverified comparative measurement; standard reference is not confirmed conformity
Measured 0/10 run target; valid complete-break n=0; mean n/a kJ/m²; sample SD n/a kJ/m²; CV n/a%; min n/a; max n/a kJ/m²
No break 0; invalid 0; excluded 0. Conditions and runs are separate. Batch rows overlap their condition total; do not sum them.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 3.783 kJ/m²; Std. Dev 0.109 kJ/m²; CV 2.873%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 4.659 kJ/m²; Std. Dev 1.86 kJ/m²; CV 39.918%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 4.435 kJ/m²; Std. Dev 0.35 kJ/m²; CV 7.888%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 6.582 kJ/m²; Std. Dev 2.228 kJ/m²; CV 33.85%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 4.782 kJ/m²; Std. Dev 0.289 kJ/m²; CV 6.039%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 5.851 kJ/m²; Std. Dev 1.307 kJ/m²; CV 22.331%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 39.349 kJ/m²; Std. Dev 3.768 kJ/m²; CV 9.576%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 26.715 kJ/m²; Std. Dev 2.097 kJ/m²; CV 7.851%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 7.155 kJ/m²; Std. Dev 1.038 kJ/m²; CV 14.505%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 3.891 kJ/m²; Std. Dev 0.465 kJ/m²; CV 11.948%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 4.237 kJ/m²; Std. Dev 0.337 kJ/m²; CV 7.962%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 3.889 kJ/m²; Std. Dev 0.164 kJ/m²; CV 4.217%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 3.897 kJ/m²; Std. Dev 0.564 kJ/m²; CV 14.472%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 3.762 kJ/m²; Std. Dev 0.143 kJ/m²; CV 3.808%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 4.254 kJ/m²; Std. Dev 0.738 kJ/m²; CV 17.346%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 7.042 kJ/m²; Std. Dev 9.988 kJ/m²; CV 141.822%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 3.421 kJ/m²; Std. Dev 0.234 kJ/m²; CV 6.83%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 3.715 kJ/m²; Std. Dev 0.096 kJ/m²; CV 2.592%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 3.605 kJ/m²; Std. Dev 0.381 kJ/m²; CV 10.564%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 5.462 kJ/m²; Std. Dev 0.314 kJ/m²; CV 5.756%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 5.113 kJ/m²; Std. Dev 0.136 kJ/m²; CV 2.659%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 9.363 kJ/m²; Std. Dev 13.388 kJ/m²; CV 142.982%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 3.444 kJ/m²; Std. Dev 0.094 kJ/m²; CV 2.721%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 7.017 kJ/m²; Std. Dev 1.14 kJ/m²; CV 16.245%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 8.767 kJ/m²; Std. Dev 1.883 kJ/m²; CV 21.478%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 5.167 kJ/m²; Std. Dev 2.218 kJ/m²; CV 42.932%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 3.765 kJ/m²; Std. Dev 0.121 kJ/m²; CV 3.215%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 3.629 kJ/m²; Std. Dev 0.417 kJ/m²; CV 11.491%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 3.862 kJ/m²; Std. Dev 0.179 kJ/m²; CV 4.623%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 3.807 kJ/m²; Std. Dev 0.086 kJ/m²; CV 2.272%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 3.556 kJ/m²; Std. Dev 0.435 kJ/m²; CV 12.243%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 11.935 kJ/m²; Std. Dev 1.579 kJ/m²; CV 13.23%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 17.495 kJ/m²; Std. Dev 2.716 kJ/m²; CV 15.523%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 5.204 kJ/m²; Std. Dev 0.33 kJ/m²; CV 6.348%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 6.324 kJ/m²; Std. Dev 0.61 kJ/m²; CV 9.647%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-21
Instrument readings in kJ/m²
Mean 6.434 kJ/m²; Std. Dev 1.01 kJ/m²; CV 15.698%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-21
Instrument readings in kJ/m²
Mean 24.329 kJ/m²; Std. Dev 16.382 kJ/m²; CV 67.333%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 8.999 kJ/m²; Std. Dev 3.793 kJ/m²; CV 42.147%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 25.357 kJ/m²; Std. Dev 4.877 kJ/m²; CV 19.234%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 3.934 kJ/m²; Std. Dev 0.268 kJ/m²; CV 6.802%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 2.6 kJ/m²; Std. Dev 0.123 kJ/m²; CV 4.741%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 2.277 kJ/m²; Std. Dev 0.053 kJ/m²; CV 2.346%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 3.754 kJ/m²; Std. Dev 0.222 kJ/m²; CV 5.914%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 2.659 kJ/m²; Std. Dev 0.373 kJ/m²; CV 14.039%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 3.198 kJ/m²; Std. Dev 0.186 kJ/m²; CV 5.808%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 7.664 kJ/m²; Std. Dev 2.03 kJ/m²; CV 26.494%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 5.197 kJ/m²; Std. Dev 0.4 kJ/m²; CV 7.707%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 3.648 kJ/m²; Std. Dev 0.363 kJ/m²; CV 9.95%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 2.959 kJ/m²; Std. Dev 0.129 kJ/m²; CV 4.368%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 3.967 kJ/m²; Std. Dev 0.804 kJ/m²; CV 20.265%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 3.213 kJ/m²; Std. Dev 0.204 kJ/m²; CV 6.361%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 3.995 kJ/m²; Std. Dev 0.969 kJ/m²; CV 24.267%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 3.65 kJ/m²; Std. Dev 0.651 kJ/m²; CV 17.834%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.738 kJ/m²; Std. Dev 0.162 kJ/m²; CV 9.298%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.567 kJ/m²; Std. Dev 0.654 kJ/m²; CV 41.753%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 2.122 kJ/m²; Std. Dev 0.784 kJ/m²; CV 36.937%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 2.819 kJ/m²; Std. Dev 0.889 kJ/m²; CV 31.537%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 2.546 kJ/m²; Std. Dev 0.784 kJ/m²; CV 30.814%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 2.239 kJ/m²; Std. Dev 0.705 kJ/m²; CV 31.474%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 5.338 kJ/m²; Std. Dev 0.525 kJ/m²; CV 9.838%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 4.612 kJ/m²; Std. Dev 0.969 kJ/m²; CV 21.008%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 4.255 kJ/m²; Std. Dev 0.72 kJ/m²; CV 16.914%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 3.168 kJ/m²; Std. Dev 0.245 kJ/m²; CV 7.728%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 5.867 kJ/m²; Std. Dev 0.103 kJ/m²; CV 1.762%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 6.159 kJ/m²; Std. Dev 0.2 kJ/m²; CV 3.245%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 4.298 kJ/m²; Std. Dev 0.426 kJ/m²; CV 9.903%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 4.467 kJ/m²; Std. Dev 0.239 kJ/m²; CV 5.352%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.946 kJ/m²; Std. Dev 0.245 kJ/m²; CV 12.608%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 1.109 kJ/m²; Std. Dev 0.542 kJ/m²; CV 48.87%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 7.437 kJ/m²; Std. Dev 0.453 kJ/m²; CV 6.096%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 7.476 kJ/m²; Std. Dev 0.254 kJ/m²; CV 3.404%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 10.054 kJ/m²; Std. Dev 0.889 kJ/m²; CV 8.839%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 9.663 kJ/m²; Std. Dev 0.771 kJ/m²; CV 7.974%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 1.1 kJ/m²; Std. Dev 0.043 kJ/m²; CV 3.916%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 2.826 kJ/m²; Std. Dev 0.773 kJ/m²; CV 27.357%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 6.482 kJ/m²; Std. Dev 0.353 kJ/m²; CV 5.441%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 5.734 kJ/m²; Std. Dev 0.223 kJ/m²; CV 3.884%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 6.654 kJ/m²; Std. Dev 0.577 kJ/m²; CV 8.672%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 23.71 kJ/m²; Std. Dev 2.19 kJ/m²; CV 9.236%; Samples 6; Confidence 6
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 6.369 kJ/m²; Std. Dev 0.345 kJ/m²; CV 5.422%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 5.606 kJ/m²; Std. Dev 0.734 kJ/m²; CV 13.096%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-28
Instrument readings in kJ/m²
Mean 8.932 kJ/m²; Std. Dev 1.51 kJ/m²; CV 16.904%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 7.8 kJ/m²; Std. Dev 1.24 kJ/m²; CV 15.892%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.648 kJ/m²; Std. Dev 0.132 kJ/m²; CV 7.992%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 0.841 kJ/m²; Std. Dev 0.28 kJ/m²; CV 33.34%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 6.351 kJ/m²; Std. Dev 1.112 kJ/m²; CV 17.513%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 8.593 kJ/m²; Std. Dev 4.095 kJ/m²; CV 47.66%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 2.107 kJ/m²; Std. Dev 0.375 kJ/m²; CV 17.807%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 1.912 kJ/m²; Std. Dev 0.232 kJ/m²; CV 12.118%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 9.415 kJ/m²; Std. Dev 0.433 kJ/m²; CV 4.595%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 8.659 kJ/m²; Std. Dev 0.256 kJ/m²; CV 2.956%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 7.828 kJ/m²; Std. Dev 0.711 kJ/m²; CV 9.088%; Samples 5; Confidence 5
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 7.167 kJ/m²; Std. Dev 0.3 kJ/m²; CV 4.18%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 8.994 kJ/m²; Std. Dev 1.61 kJ/m²; CV 17.896%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 9.753 kJ/m²; Std. Dev 2.049 kJ/m²; CV 21.011%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 7.414 kJ/m²; Std. Dev 0.151 kJ/m²; CV 2.037%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 7.517 kJ/m²; Std. Dev 0.247 kJ/m²; CV 3.292%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 65.708 kJ/m²; Std. Dev 9.686 kJ/m²; CV 14.741%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 123.714 kJ/m²; Std. Dev 9.88 kJ/m²; CV 7.986%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 26.387 kJ/m²; Std. Dev 1.553 kJ/m²; CV 5.885%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 10.165 kJ/m²; Std. Dev 1.496 kJ/m²; CV 14.715%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 5.07 kJ/m²; Std. Dev 0.134 kJ/m²; CV 2.636%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 5.3 kJ/m²; Std. Dev 0.101 kJ/m²; CV 1.905%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 19.916 kJ/m²; Std. Dev 1.833 kJ/m²; CV 9.205%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 24.332 kJ/m²; Std. Dev 5.763 kJ/m²; CV 23.683%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 10.124 kJ/m²; Std. Dev 0.607 kJ/m²; CV 5.993%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 10.152 kJ/m²; Std. Dev 0.73 kJ/m²; CV 7.193%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 34.295 kJ/m²; Std. Dev 15.966 kJ/m²; CV 46.553%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 20.818 kJ/m²; Std. Dev 4.598 kJ/m²; CV 22.088%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 24.962 kJ/m²; Std. Dev 8.789 kJ/m²; CV 35.208%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 65.179 kJ/m²; Std. Dev 28.002 kJ/m²; CV 42.962%; Samples 8; Confidence 8
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 23.71 kJ/m²; Std. Dev 1.999 kJ/m²; CV 8.431%; Samples 7; Confidence 7
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 14.068 kJ/m²; Std. Dev 1.443 kJ/m²; CV 10.259%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 11.78 kJ/m²; Std. Dev 5.7 kJ/m²; CV 48.387%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 23.206 kJ/m²; Std. Dev 2.795 kJ/m²; CV 12.046%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 6.98 kJ/m²; Std. Dev 0.169 kJ/m²; CV 2.423%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 7 kJ/m²; Std. Dev 0.271 kJ/m²; CV 3.864%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 10.165 kJ/m²; Std. Dev 0.625 kJ/m²; CV 6.153%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 11.666 kJ/m²; Std. Dev 0.364 kJ/m²; CV 3.122%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 11.301 kJ/m²; Std. Dev 0.272 kJ/m²; CV 2.405%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 11.561 kJ/m²; Std. Dev 0.217 kJ/m²; CV 1.874%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 5.548 kJ/m²; Std. Dev 0.183 kJ/m²; CV 3.297%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 4.356 kJ/m²; Std. Dev 1.229 kJ/m²; CV 28.218%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 2.989 kJ/m²; Std. Dev 1.03 kJ/m²; CV 34.45%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 4.159 kJ/m²; Std. Dev 0.472 kJ/m²; CV 11.358%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 9.866 kJ/m²; Std. Dev 0.235 kJ/m²; CV 2.383%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-03
Instrument readings in kJ/m²
Mean 9.673 kJ/m²; Std. Dev 0.348 kJ/m²; CV 3.602%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 3.039 kJ/m²; Std. Dev 0.566 kJ/m²; CV 18.631%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 3.005 kJ/m²; Std. Dev 0.152 kJ/m²; CV 5.045%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 11.868 kJ/m²; Std. Dev 0.462 kJ/m²; CV 3.89%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 12.017 kJ/m²; Std. Dev 0.194 kJ/m²; CV 1.617%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 13.884 kJ/m²; Std. Dev 0.48 kJ/m²; CV 3.457%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 13.632 kJ/m²; Std. Dev 0.554 kJ/m²; CV 4.062%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 5.764 kJ/m²; Std. Dev 0.85 kJ/m²; CV 14.749%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 6.103 kJ/m²; Std. Dev 0.927 kJ/m²; CV 15.188%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 5.898 kJ/m²; Std. Dev 0.458 kJ/m²; CV 7.76%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 5.716 kJ/m²; Std. Dev 0.316 kJ/m²; CV 5.535%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 5.867 kJ/m²; Std. Dev 0.809 kJ/m²; CV 13.795%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 5.498 kJ/m²; Std. Dev 0.732 kJ/m²; CV 13.314%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 4.672 kJ/m²; Std. Dev 0.484 kJ/m²; CV 10.357%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-02
Instrument readings in kJ/m²
Mean 4.397 kJ/m²; Std. Dev 0.775 kJ/m²; CV 17.629%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 19.164 kJ/m²; Std. Dev 5.524 kJ/m²; CV 28.823%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 18.38 kJ/m²; Std. Dev 0.917 kJ/m²; CV 4.987%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 4.815 kJ/m²; Std. Dev 0.399 kJ/m²; CV 8.281%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 4.684 kJ/m²; Std. Dev 0.635 kJ/m²; CV 13.564%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.667 kJ/m²; Std. Dev 0.676 kJ/m²; CV 40.568%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 1.965 kJ/m²; Std. Dev 0.697 kJ/m²; CV 35.483%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 8.43 kJ/m²; Std. Dev 0.595 kJ/m²; CV 7.053%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 9.935 kJ/m²; Std. Dev 0.655 kJ/m²; CV 6.594%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 9.884 kJ/m²; Std. Dev 0.302 kJ/m²; CV 3.057%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 9.91 kJ/m²; Std. Dev 0.512 kJ/m²; CV 5.163%; Samples 9; Confidence 9
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 8.907 kJ/m²; Std. Dev 0.604 kJ/m²; CV 6.785%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 8.674 kJ/m²; Std. Dev 0.792 kJ/m²; CV 9.135%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 17.214 kJ/m²; Std. Dev 0.625 kJ/m²; CV 3.632%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 16.462 kJ/m²; Std. Dev 0.508 kJ/m²; CV 3.085%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 8.161 kJ/m²; Std. Dev 0.209 kJ/m²; CV 2.563%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-29
Instrument readings in kJ/m²
Mean 8.556 kJ/m²; Std. Dev 0.258 kJ/m²; CV 3.019%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 18.772 kJ/m²; Std. Dev 0.281 kJ/m²; CV 1.495%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-09-30
Instrument readings in kJ/m²
Mean 19.057 kJ/m²; Std. Dev 0.964 kJ/m²; CV 5.057%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 14.986 kJ/m²; Std. Dev 0.641 kJ/m²; CV 4.274%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-01
Instrument readings in kJ/m²
Mean 16.137 kJ/m²; Std. Dev 1.031 kJ/m²; CV 6.387%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 4.373 kJ/m²; Std. Dev 0.127 kJ/m²; CV 2.91%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 4.7 kJ/m²; Std. Dev 0.44 kJ/m²; CV 9.353%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Izod Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 38.345 kJ/m²; Std. Dev 2.077 kJ/m²; CV 5.417%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Charpy Impact Strength · 2026-10-04
Instrument readings in kJ/m²
Mean 37.801 kJ/m²; Std. Dev 0.917 kJ/m²; CV 2.426%; Samples 10; Confidence 10
No break 0; invalid 0; excluded 0.
Comparative measurements; standard conformity unverified.
Pricing intelligence
Explore public MSRP, measured performance per dollar and comparable value rankings. Filters are synchronized with the Filament Database so both tabs always use the same visible material set.
| Material | Type | MSRP | MSRP USD/kg | Landed USD/kg | Overall | Value index | Price checked |
|---|
Measured material behavior
Compare mean results for flexible filaments. Hover over a bar for sample statistics, or click to keep them open.
Click to select or deselect. No selection shows all matching filaments.
3DPIceland Labs
Published parameter studies and verified native test runs. Full chart visualization arrives in the dedicated Experimental Lab dashboard milestone.
Independent filament testing and manufacturer intelligence
3DPIceland Labs measures tensile strength, impact resistance, stiffness and layer adhesion using one controlled, repeatable workflow. Manufacturers receive independent technical visibility, comparable engineering context and long-term discoverability across the database, rankings, reports and relevant video coverage.
Manufacturer submission portal
Send production filament for inclusion in the 3DPIceland Engineering Platform. Materials enter the same documented print, measurement, calculation and verification pipeline as the rest of the database. Results are independent and data-driven; paid placement is not required and does not influence rankings.
Manufacturer enquiries: iskort@iskort.is
Structured email submission
Complete the form and your email application will open with a structured enquiry addressed to 3DPIceland Labs. No information is uploaded or stored by this website.
Measured manufacturer directory
Profiles, material coverage and engineering highlights below are generated from the canonical SQLite database and verified result summaries during every website export.
Sustainable materials
USA made, consistent quality
Prototyping, functional parts
Bio-based materials
Industrial polymers
Engineering quality
Industrial parts, tooling
European production
Precision manufacturing
Excellent consistency
Functional parts
Local production
High-speed printing
Optimized profiles
General & high-speed printing
Refill options
Material innovation
Innovative materials
Engineering, design
Renewable energy
Precision manufacturing
Tight tolerances
Functional parts
European production
Engineering polymers
Engineering materials
Industrial parts
CO₂ conscious production
Professional printing
German manufacturing, consistent quality
Functional parts, prototyping
Green electricity, eco packaging
Performance materials
Excellent quality
Engineering, design
European production
Reliable production
USA manufacturing
Education, industry
Local production
Broad material offering
Wide availability
General printing
Standard initiatives
Specialty materials
Exceptional finish, unique colors
Display models, decorative prints
Unknown
Engineering polymers
Outstanding consistency
Functional parts
Cardboard spools
Value engineering
Good value
Hobby & professional
Standard initiatives
Specialty materials
Unique materials
Specialty printing
Local production
Reliability
Exceptional QC
Professional printing
Recycled packaging
Consumer materials
Affordable
Everyday printing
Standard initiatives
European production
Good price/performance
General printing
European production
Engineering composites
Wide engineering portfolio
Industrial components
Standard initiatives
Value materials
Excellent value
General printing
Refill options
Consumer ecosystem
Excellent value
General printing
Cardboard spools
Engineering resins & filaments
High-performance materials
Functional prototypes
Standard initiatives
Affordable materials
Low cost
Hobby printing
Standard initiatives
Engineering & high-performance materials
Wide portfolio, strong quality control
General, engineering & industrial printing
ReFill system, recycled & bio-based materials
Consumer & prosumer 3D printing materials
Broad filament range, competitive pricing, high production capacity, strong aesthetic PLA selection, refill options
Makers, hobbyists, creators & prototyping
Refill system, eco-conscious materials & localized production
Engineering-grade polymers
Broad range, consistent quality
Prototyping, functional parts
rPET, EU production
Functional polymers, custom extrusion
US manufacturing, diameter control, custom production
Prototyping, functional parts, jigs and fixtures
Recycled PLA range, recycled-paper spools
Standalone calculator based on the Print Farm Academy Excel sheet. Fill in the blue input fields to estimate material cost, labor, machine time, packaging, landed cost, and suggested customer pricing.
Labor cost uses print/post-processing labor, customer consulting time, and parts design / changes time.
Estimated Uptime uses a percentage from 0 to 100; enter 50 for 50%.
| Item | Name | Qty | Unit Cost | Total |
|---|
| Item | Name | Qty | Unit Cost | Total |
|---|
Final price is calculated from the landed cost and the user-defined target margin.
3D Printing Price Quote
Quote #:
Date:
Prepared using a calculator based on the Print Farm Academy pricing sheet.
| Description | Qty | Unit Price | Total |
|---|
This quote is an estimate based on the supplied project information. Shipping is shown separately when entered in the calculator. Final pricing may change if the model, material, quantity, design requirements, shipping, or delivery requirements change.
One canonical catalog for the complete public report portfolio.

3DPIceland Labs
Generated with 3DPIceland Engineering Platform v70.0.4 DIRECT-IMPACT-METHODOLOGY - Izod and Charpy Methodology
2026-10-04 18:13:41
Dataset identity, public test coverage, material/manufacturer distribution and the complete public score ledger.
Open HTML · PDFMaterial family: ABS
Open HTML · PDFMaterial family: ASA
Open HTML · PDFMaterial family: HIPS
Open HTML · PDFMaterial family: PA12
Open HTML · PDFMaterial family: PA6
Open HTML · PDFMaterial family: PC
Open HTML · PDFMaterial family: PC/ABS
Open HTML · PDFMaterial family: PC/PBT
Open HTML · PDFMaterial family: PCTG
Open HTML · PDFMaterial family: PEBA
Open HTML · PDFMaterial family: PET
Open HTML · PDFMaterial family: PETG
Open HTML · PDFMaterial family: PLA
Open HTML · PDFMaterial family: PP
Open HTML · PDFMaterial family: TPE
Open HTML · PDFMaterial family: TPU
Open HTML · PDFManufacturer: 3D Fuel
Open HTML · PDFManufacturer: Add:North
Open HTML · PDFManufacturer: Atomic
Open HTML · PDFManufacturer: BambuLab
Open HTML · PDFManufacturer: Bedrock 3D
Open HTML · PDFManufacturer: Coex 3D
Open HTML · PDFManufacturer: ColorFabb
Open HTML · PDFManufacturer: DasFilament
Open HTML · PDFManufacturer: Elegoo
Open HTML · PDFManufacturer: Eryone
Open HTML · PDFManufacturer: Extrudr
Open HTML · PDFManufacturer: FilaFarm
Open HTML · PDFManufacturer: Fillamentum
Open HTML · PDFManufacturer: IC3D
Open HTML · PDFManufacturer: Landu
Open HTML · PDFManufacturer: MatterHackers
Open HTML · PDFManufacturer: Polyalchemy
Open HTML · PDFManufacturer: Polymaker
Open HTML · PDFManufacturer: Prima Creator
Open HTML · PDFManufacturer: ProtoPasta
Open HTML · PDFManufacturer: Prusa3D
Open HTML · PDFManufacturer: Siraya Tech
Open HTML · PDFManufacturer: Spectrum
Open HTML · PDFManufacturer: Sunlu
Open HTML · PDFManufacturer: Thorwell
Open HTML · PDFManufacturer: Winkle
Open HTML · PDFManufacturer: Yasin
Open HTML · PDF3DPIceland Labs Mechanical Testing Methodology
This page documents the practical, repeatable test workflow behind the public database. It combines an accessible explanation with technical details for readers who want to understand specimen orientation, measurements, calculations, repeatability and known limitations.
Scope: These are comparative 3DPIceland Labs measurements produced with consistent in-house equipment and procedures. They are not certified ISO or ASTM datasheet values and should not be interpreted as a replacement for accredited laboratory testing.
The objective is controlled comparison across filament brands, material families, colors and reinforced variants. A result is most useful when the same specimen design, orientation, equipment and calculation path are used repeatedly. The database therefore emphasizes consistency and transparency over claiming laboratory certification.
Results are designed to compare materials measured within this system. Direct comparison with manufacturer datasheets requires caution because standards, conditioning and specimen geometry may differ.
Flat and upright specimens reveal different behavior. Flat specimens primarily represent strength through deposited roads, while upright specimens emphasize bonding between printed layers.
Multiple specimens are measured where applicable. Averages, variation, sample counts and confidence indicators help show how stable each result is.
Specimens are printed using a controlled internal test profile so that material-to-material differences are not hidden by changing geometry or general print strategy. Material-specific temperature requirements may differ, but the comparative workflow keeps the remaining relevant settings consistent within each test family.
Important: Print temperature, moisture, cooling, machine calibration, color additives and manufacturing batch can all affect the measured result. The database represents the tested spool and documented print conditions.
Mechanical test 01
What it measures: The peak pulling force required to break a narrowed printed specimen. Flat specimens are presented publicly as Tensile Strength; upright specimens are presented as Layer Adhesion Strength.
Peak force is converted to stress using the effective printed cross-sectional area at the designed failure zone. Internal void space is excluded rather than treating the complete outer rectangle as solid.
The native calculation engine uses a canonical effective cross-section of approximately 6.5016 mm². The fixture is designed for a practical range up to roughly 500 N. Fracture should occur in the narrowed gauge region; abnormal fixture or removal failures are excluded.
Direct instrument measurement
What it measures: Impact response with the specimen held as a cantilever in the Izod fixture. The operator uses the new pendulum instrument for the ISO 180 method family. This identifies the method family; it does not certify the printed result or assert a verified standard edition, conditioning protocol or accredited test.
The instrument supplies kJ/m² directly. Up to ten readings are entered for each material in the Izod table; the app does not apply the legacy angle calculation or divide the readings by area again. Print orientation describes how the coupon was printed, independently of its position in the test fixture.
Record a no-break outcome as NB; it is retained but excluded from numeric statistics, not replaced by zero or a maximum value. Partial or abnormal breaks need failure notes and careful interpretation.
Izod values are compared within the Izod method. They cannot be converted to Charpy or Legacy Impact values by a universal factor.
Direct instrument measurement
What it measures: Impact response with the specimen resting across two supports in the Charpy fixture. The operator uses the new pendulum instrument for the ISO 179 method family. The fixture and loading differ from Izod, even when both coupons were printed flat.
The instrument supplies kJ/m² directly. Up to ten readings are entered for each material in the Charpy table. The app calculates statistics from these readings without repeating the instrument's energy-to-area conversion.
NB means no break: the outcome is retained and excluded from numeric statistics, never treated as zero or an invented numerical result. Compare like specimen geometry, notch, printing conditions and failure modes within the same method.
ISO 179 identifies the method family here; the recorded data do not independently establish a particular standard edition, complete protocol compliance or certified material-datasheet values.
Historical comparative test
What it measures: How much energy a printed specimen absorbs when struck by a pendulum hammer. A material that stops more of the hammer's motion receives a higher impact result.
The no-sample swing establishes the available pendulum energy. The specimen's remaining swing is used to calculate energy lost by the hammer, normalized by the effective specimen cross-section. Partial fracture, deformation and the hammer dragging along the specimen can contribute to that loss; it must not always be interpreted as clean fracture energy.
The native calculation engine uses a no-sample reference angle of approximately 105.411° and a net section of approximately 0.00004816 m². Repeated empty swings indicated about 3% spread between the highest and lowest readings during early validation.
Legacy Impact is retained as a historical comparison within the old method. It is not interchangeable with Izod or Charpy. Its radar axis shows the mean of available Flat/Upright values as a percentage of the matching rig maximum, capped at 100%; it is excluded from modern Overall and Consistency scores. With 2.743860924 J available energy and 48.1603 mm² net area, that maximum is approximately 56.9735 kJ/m².
Mechanical test 03
What it measures: Resistance to bending under a defined load. A higher calculated modulus means the material deflects less and is therefore stiffer.
Measured center deflection is combined with load, support span and specimen geometry using the fixture's beam-deflection calculation to estimate stiffness in MPa.
The native calculation path uses approximately 1.058774 mm per revolution, a 118.2 mm support span, a 5.47 N load and a second moment of area of approximately 34.679467 mm⁴. Early same-specimen repeats showed roughly 5% variation after fixture repair and validation.
Mechanical test 04
What it measures: Resistance of a printed TPU cylinder to 20% Z-direction compression. A higher force means greater resistance under this exact method, not automatically a better material.
The 30 s point was selected because force change had slowed during method development, reducing sensitivity to small timing error. It does not claim equilibrium. If 20% strain cannot be reached within the FK 500 measurement range, the target is recorded as not reached; 500 N is never invented as a target result.
This is an in-house comparative method, not ASTM D575 or ISO 7743. ISO 7743 informed development, but the specimen, manual approach, 20% target and hold readings are specific to 3DPIceland Labs. Manual rate, first contact, print quality, dimensions and fixture compliance can affect results. Specimen spread describes method repeatability, not a complete uncertainty budget.
Mechanical test 05
What it measures: The nearby under-specimen BlueDOT probe-indicated fixture temperature when a flat specimen reaches 2.00 mm mid-span deflection. The governed result is recorded in °C under method 3dp-thermal-deflection-fixture-v1.
A higher result means the specimen reached the defined fixture deflection at a higher nearby probe temperature within this comparative workflow. It is not a certified heat-deflection temperature or a substitute for application-specific thermal validation.
The BlueDOT has no user calibration option. This fixture-specific method is not ASTM D648 or ISO 75 HDT, does not claim specimen-core temperature and does not infer missing results. Historical values remain tied to their immutable method version.
The displayed engineering value is based on the mean of the valid specimen measurements available for that orientation and test.
Sample standard deviation uses n−1. CV is sample SD divided by the mean × 100. They describe observed independent specimens, not fixed accuracy or uncertainty for future measurements.
The confidence indicator combines sample coverage and measurement consistency. It is an internal indicator, not a 95% confidence interval. Lower confidence means the result should be interpreted more cautiously; it does not mean the material itself is weak.
The consistency score is 100 minus the average available tensile Flat/Upright, Izod and Charpy CV%, minus an incomplete-sample penalty. Legacy Impact does not contribute. It describes repeatability inside this test workflow, not accredited instrument accuracy or an industry standard.
With complete ten-specimen sets and no sample penalty, these bands correspond approximately to average CV ranges of 0–10%, 10–15%, 15–20%, 20–30%, 30–40% and above 40% respectively.
Each method reports its own numeric mean, sample standard deviation, CV%, valid sample count and internal confidence indicator. Blank cells and NB outcomes do not count as numeric samples. An unavailable statistic remains blank rather than becoming zero.
For both methods, 80 kJ/m² corresponds to 100 points; 40 kJ/m² corresponds to 50 points. Values above 80 retain their measured value while their score is capped at 100. This is a versioned 3DPIceland comparison reference, not an ISO grade, instrument capacity or physical material limit. A later reference change must be documented.
Overall uses five equally weighted score families: tensile, stiffness, consistency, layer adhesion and impact. The impact family is the average of Izod and Charpy scores and requires both methods. All five families must be available for Overall; missing measurements are not zero. Legacy Impact and thermal remain separate from Overall.
The most reliable use of this database is comparison between materials tested by the same 3DPIceland Labs workflow—not treating an individual number as a certified design allowable.
FDM parts are direction-dependent. Flat specimens emphasize the deposited roads, while upright specimens force the load across many layer interfaces. Reporting both exposes anisotropy that one orientation would hide.
Short fibers often increase rigidity and dimensional stability, but they can reduce ductility and do not automatically improve impact resistance or bonding between layers. Strength, stiffness, toughness and layer adhesion are separate properties.
Fragile specimens can fail during printing, removal from the build plate, brim removal or fixture preparation. Only usable measurements are included, and sample coverage is reflected in confidence.
They can provide useful context, but not a one-to-one replacement. Manufacturer values may use injection-molded specimens, standardized conditioning, different geometry and certified equipment.
No. The best material depends on the application. High stiffness may be desirable for dimensional stability, while a lower-stiffness, higher-impact material may be better for clips, guards or parts exposed to shocks.
Technical documentation
The Level 3 whitepaper expands this page with the documented equipment context, specimen geometry, calculation ownership, statistics, limitations and revision history, including separate Izod, Charpy and Legacy Impact methods.
Download Engineering Whitepaper (PDF)Current methodology version: 1.0 · Generated by the native Documentation EngineWebsite export generates this PDF using the native Documentation Engine. The website methodology and whitepaper are maintained together under the same release and verification process.